2Camera Output Timing Charts

2.1

Normal Mode

 

(Setting

10H: 1XX0XXXX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal Full Scanning

 

Partial Full Scanning

 

1/2 Partial Scanning

1/4 Partial Scanning

Clock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Normal

x2/3

x1/3

 

Normal

x2/3

x1/3

 

Normal

x2/3

x1/3

Normal

x2/3

x1/3

(MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frame

89.9

59.4

29.9

 

 

 

 

 

 

 

 

 

 

 

Rate

 

94.4

62.9

31.5

 

180.1

120.1

60.1

360.3

240.2

120.1

(90)

(60)

(30)

 

 

(Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock Speed: 36.8181 MHzNormal)、24.5454 MHzx2/3)、12.2727 MHzx1/3

 

 

2.1.1Horizontal Timing

1 CLK = 81.4816 ns at 30fps

1 CLK = 40.7408 ns at 60fps

1 CLK = 27.1605 ns at 90fps

LVAL

 

780 CLK

 

 

One horizontal (1H)

 

 

 

 

DVAL

132 CLK648 CLK132 CLK

FVAL

39

93 CLK

CLK

Video out

 

132 CLK

 

 

 

648 CLK

 

 

 

132 CLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal blanking

Video output

 

 

FVL030B1

5/32

User’s Guide Rev. 1.01

 

Page 5
Image 5
Ricoh FV-L030B1 manual Normal Mode Setting 10H, Horizontal Timing