29/31
FV-L500B1
User’s Guide Rev. 1.01
Command No. Command Descriptions
68H:
DIGITAL_
CLAMP[7N0]
[Digital clamp] Initial data: DIGITAL_CLAMP[7..0] = 0
Sets the digital clamp.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D5: No function Always set as “000”
D4: Mirror image 0: Normal image 1: Mirror image
D3: No function Always set as “0”
D2: Clamp mode 0: Auto adjust 1: Manual adjust
D1 to D0: No function Always set as “00”
The following two settings have to be set when the “manual adjust” is selected at the clamp mode:
Manual digital clamp (Left): MD-CLAMP_L[15..0] (6A & 6BH)
Manual digital clamp (Right): MD_CLAMP_R[15..0] (6C & 6DH)
6AH:
MD_CLAMP_L
[7N0]
6BH:
MD_CLAMP_L
[15N8]
[Manual digital clamp (Left)]
Initial data: MD_CLAMP_L[15..0] = The factory adjusted value, data range: 0 to 1023
Sets the manual digital clamp for the left s ide of the image when the manual adjust is selected at the digital
clamp (68H).
6CH:
MD_CLAMP_R
[7N0]
6CH:
MD_CLAMP_R
[15N8]
[Manual digital clamp (Right)]
Initial data: MD_CLAMP_R[15..0] = The factory adjusted value, data range: 0 to 1023
Sets the manual digital clamp for the right side of the image when the manual adjust is selected at the digital
clamp (68H).
78H:
TESTP[7N0]
[Test pattern selection] Initial data: TESTP[7..0] = 0
Sets the test pattern output from the camera.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
00H: Video output 01H: Gray scale
02H: Ramp wave 03H: Uniform gray level (100% white)
04H: Uniform gray level (variable level) 05H: Color bar (RGB bayer)
Others: Black