OptionsLimitation
❒Only one optional interface board can be installed in the machine at a time.
Therefore, the optional IEEE 1394 interface board, the IEEE 802.11b interface
unit, the IEEE 1284 interface board, and Bluetooth interface unit cannot be in-
stalled concurrently.
IEEE 1394 Interface Board Type B
❖
❖❖
❖Transmission spec.:
IEEE 1394
❖
❖❖
❖Interface:
IEEE std 1394-1995 compliant
IEEE std 1394a-2000 compliant
❖
❖❖
❖Device class:
SCSI print (Windows 2000/XP, Windows Server 2003)
IP over 1394 (Windows Me/XP, Windows Server 2003)
❖
❖❖
❖Protocol:
SBP-2 (SCSI print)
TCP/IP (IP over 1394)
❖
❖❖
❖Interface connector:
IEEE 1394 (6 pin × 2)
❖
❖❖
❖Required cable:
1394 interface cable (6 pin x 4 pin, 6 pin x 6 pin)
Important
❒You cannot plug devices together to create loops.
❒Do not use cable that is more than 4.5 meters in length.
❖
❖❖
❖Data transfer speed:
Maximum 400 Mbps
❖
❖❖
❖Connectable number of devices on a bus:
Maximum 63
❖
❖❖
❖Allowed cable hops on a bus:
Maximum 16
❖
❖❖
❖Power supply:
Non external power supply
Cable Power repeated (IEEE 1394a-2000 compliant)
JupiterC2EN-Print-F2_FM.book Page 154 Friday, December 17, 2004 8:17 PM