Tank

!DANGER:

Never attempt to repair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explo- sion. Always replace worn, cracked or damaged tanks.

NOTICE:

Drain liquid from tank daily.

The tank should be carefully inspected at a minimum of once a year. Look for cracks forming near the welds. If a crack is detected, remove pressure from tank immediately and replace.

Filter Removal, Inspection and Replacement

To change a filter, pull off the filter housing cover. If filter element is dirty, replace element or entire filter.

Lubrication

This is an oilless type compressor requiring no lubrication.

Storage

1.When not in use, compressor should be stored in a cool dry place.

2.Tank should be drained of moisture.

3.Hose should be disconnected and hung open ends down to allow any moisture to drain.

Maintenance Schedule

 

Operation

Daily

Weekly

 

 

Drain Tank

 

 

 

Check Air Filter

 

 

 

Check Safety Valve

 

 

 

Blow Dirt From Inside Motor

 

 

 

 

 

 

 