Troubleshooting

!WARNING:

For your own safety do not try and run the air compressor while troubleshooting.

TROUBLEPROBABLE CAUSEREMEDY

 

 

 

 

 

 

 

 

Compressor will not

1. Unit is plugged into

1. Remove extension cord

run

extension cord

 

 

 

2. No electrical power

2. Plugged in? Check

 

 

fuse/breaker or motor

 

 

overload

 

3. Blown fuse

3. Replace blown fuse

 

4. Breaker open

4. Reset, determining why

 

 

problem happened

 

5. Thermal overload open

5. Motor will restart when

 

 

cool

 

6. Pressure switch bad

6. Replace

 

 

 

Motor hums but can-

1. Low voltage

1. Check with voltmeter

not run or runs slow-

2. Unit is plugged into

2. Remove extension cord

ly

extension cord

 

 

 

3. Shorted or open motor

3. Replace motor

 

winding

 

 

 

4. Defective check valve or

4. Replace or repair

 

unloader

 

 

 

 

 

 

Fuses blow/circuit

1. Incorrect size fuse, circuit

1. Check for proper fuse, use

breaker trips repeat-

overloaded

time-delay fuse.

edly

 

Disconnect other electrical

 

 

appliances from circuit or

 

 

operate compressor on its

 

 

own branch circuit

 

2. Unit is plugged into

2. Remove extension cord

 

extension cord

 

 

 

3. Defective check valve or

3. Replace or repair

 

unloader

 

 

 

 

 

 

16