Rinnai EX08C (RHFE-202FTA), EX11C (RHFE-265FTA) installation manual Flue Manifold Installation

Models: EX08C (RHFE-202FTA) EX11C (RHFE-265FTA)

1 80
Download 80 pages 7.56 Kb
Page 21
Image 21
Flue Manifold Installation

Flue Manifold Installation

The flue manifold must exhaust to the outside. Do not exhaust into other rooms.

The flue manifold is not designed to be positioned under floors or below the heater.

The termination cannot be vertical.

This appliance can only be used with one of the five types of Rinnai flue kits. The flue kits and their dimensions are listed in the Specifications section.

Refer to the Flue Terminal Clearances section.

1.Disassemble the flue manifold The flue consists of 3 parts:

Inside Connection

Terminal

sleeve

 

inside connection

outside terminal

Disassemble the flue manifold by first pulling

 

out the inside connection. To remove the

 

outer terminal pull and release the two

 

internal ties and then pull out the outer

Sleeve

terminal.

Clearance to combustibles for the sleeve and flanges is zero inches.

2.Adjust the sleeve length

Measure wall thickness through previously drilled 3 1/8 inch (80 mm) hole.

The end of the sleeve should protrude 3/16 - 3/8 inch (5-10 mm) from the outside wall.

The sleeve is threaded for adjustment. Adjust the sleeve length to wall thickness plus 3/16 - 3/8 inch (5-10 mm).

NOTE: Do not extend beyond the red line.

For other than the “S” type flue manifold, if a shorter length is necessary an extension can be removed. Cut the outer plastic laminate (with a utility knife or similar) and remove the extension. The metal should not be cut.

Remove extension if necessary

3.Attach the sleeve

Attach to the inside wall using 3 screws arranging the flange so that the marking “TOP” is at the top.

The flange is offset 2° to allow the condensate drain to the outside.

sleeve should extend 3/16 - Manual background 3/8 in (5-10 mm)

3 screws

Rinnai Corporation EX08C, EX11C Manual

21

Page 21
Image 21
Rinnai EX08C (RHFE-202FTA), EX11C (RHFE-265FTA) installation manual Flue Manifold Installation