Connecting the Appliance

Connecting the Appliance

1. Attach the air inlet hose to the flue manifold on

a

 

either inlet position “a” or “b”.

 

The plastic tie should be tight over the sleeve.

 

The unused inlet is plugged with the rubber cap

b

supplied on the manifold.

 

2.Connect the flue elbow to the manifold while moving the appliance into position.

Flue Manifold

3.Fit the pipe stopper over the connection between the flue elbow and the manifold. Engage the hook and rotate it until it snaps against the body of the clamp.

Pipe stopper

 

 

Hook

Elbow

Manifold

 

Pipe stopper

4. Slide the insulation sleeve up to the flue manifold

Fit Clip

 

 

 

 

and slip the securing clip over the sleeve as

 

 

 

 

shown.

 

 

Slide

 

Sock

5.Install the bracket on the rear of the top spacer by tightening 2 screws.

6.Install the wall bracket with two screws. Install the top spacer by clipping the spacer into the wall brackets and attaching it to the heater with 2 screws.

Top Spacer

Spacer

Wall

2 screws

Bracket

Top Spacer

 

 

 

Bracket

 

 

 

 

 

 

Spacer

Bracket

Wall

Bracket

26

Rinnai Corporation EX08C, EX11C Manual

Page 26
Image 26
Rinnai EX11C (RHFE-265FTA) Connecting the Appliance, and slip the securing clip over the sleeve as, shown