Mounting on the wall

Temperature Controller Installation

Mounting on the wall

Follow the procedure below to install MC-91 or MCC-91 temperature controllers.

Outline of Temperature controller

1.

Determine a suitable location for the

 

controller.

2.

Make three holes in the wall as shown.

3.

Run the cable between the controller and the

 

Rinnai water heater or the controller and

 

another controller.

4.

Remove the face plate from the temperature

 

controller using a screw driver.

5.

Connect the cable to the temperature controller.

6.

Mount the controller to the wall using the

 

holes drilled in step 2.

7.

Disconnect the power from the Rinnai water

securing screw

wiring hole

securing screwTEMPERATURE CONTROL

1-21/32"

3-5/16"

 

heater.

8.

Remove the cover of the Rinnai water heater.

9.

Remove the plastic cover from the PCB and

 

electrical connections.

10.

Thread the cable through the access hole at

 

the base of the unit and connect the wires to

 

the controller terminals on the right hand side

 

bottom of the PCB.

11.

Secure the controller cable using the clamp

 

provided.

12.

Replace plastic cover over PCB and then

 

replace the cover of the Rinnai water heater.

TEMPERATURE CONTROL

CONNECTION TERMINALS

TEMPERATURE

CONTROL CABLE

CABLE CLAMP