Rinnai R98LSE-ASME Flue Terminal Clearances ANS Z21.10.3 CSA, Description, Canadian Installations

Models: R98LSE-ASME

1 40
Download 40 pages 20.09 Kb
Page 27
Image 27
Canadian Installations

VA Series Outdoor LS Manual

27

Ref

Description

Canadian Installations

US Installations

 

 

 

 

 

A

Clearance above grade, veranda, porch,

12 inches (30 cm)

12 inches (30 cm)

deck, or balcony

 

 

 

 

 

 

 

 

 

B

Clearance to window or door that may be

36 inches (91 cm)

12 inches (30 cm)

opened

 

 

 

 

 

 

 

 

 

C

Clearance to permanently closed window

*

 

*

 

 

 

 

 

 

Vertical clearance to ventilated soffit,

 

 

 

D

located above the terminal within a

*

*

 

horizontal distance of 2 feet (61 cm) from

 

 

 

 

 

 

the center line of the terminal

 

 

 

 

 

 

 

 

E

Clearance to unventilated soffit

*

 

*

 

 

 

 

 

F

Clearance to outside corner

*

 

*

 

 

 

 

 

G

Clearance to inside corner

*

 

*

 

 

 

 

 

 

3 feet (91 cm) within a

 

H

Clearance to each side of center line

height 15 feet (4.5 m)

*

extended above meter/regulator assembly

above the meter/

 

 

 

 

regulator assembly

 

 

 

 

 

I

Clearance to service regulator vent outlet

36 inches (91 cm)

*

 

 

 

 

 

 

Clearance to nonmechanical air supply

 

 

 

J

inlet to building or the combustion air inlet

36 inches (91 cm)

12 inches (30 cm)

 

to any other appliance

 

 

 

 

 

 

 

 

 

 

 

 

3 feet (91 cm) above if

K

Clearance to a mechanical air supply inlet

6 feet (1.83 m)

within 10 feet (3 m)

 

 

 

 

horizontally

 

 

 

 

 

L

Clearance above paved sidewalk or

7 feet (2.13 m)

1

*

paved driveway located on public property

 

 

 

 

 

 

 

 

 

M

Clearance under veranda, porch, deck, or

12 inches (30 cm) 2

*

balcony

 

 

 

 

 

 

 

 

 

1A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

2Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

*For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier.

Flue Terminal Clearances (ANS Z21.10.3 CSA 4.3)

Page 27
Image 27
Rinnai R98LSE-ASME Flue Terminal Clearances ANS Z21.10.3 CSA, Description, Canadian Installations, US Installations