Specifications

Specifications

Model

R63LSe

R75LSe

R94LSe

R98LSe

 

R98LSe-

 

 

ASME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Gas Consumption Btu/h

22,200

15,000

 

19,000

 

 

 

 

 

 

 

 

 

Maximum Gas Consumption Btu/h

150,000

180,000

199,000

237,000

 

Hot water capacity (Min - Max) *

0.6 - 6.3 GPM

0.6 - 7.5 GPM

0.6 - 9.4 GPM

0.6 - 9.8 GPM

(2.3 - 24 L/min)

(2.3 - 28 L/min)

(2.3 - 35.5 L/min)

(2.3 - 37 L/min)

 

 

 

 

 

 

 

 

 

 

Hot water capacity, (45ºF rise)

5.3 GPM

6.6 GPM

7.4 GPM

8.7 GPM

 

(20 L/min)

(25 L/min)

(28 L/min)

(33 L/min)

 

 

 

 

 

 

 

 

 

 

 

Default Temperature Setting (no controller)

 

 

120º F (49º C)

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Controller Default Temperature Setting

 

 

104º F (40º C)

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Temp Setting (Commercial **)

160º F (71º C)

 

185º F (85º C)

 

Maximum Temp Setting (Residential)

 

Selectable at 120º F (49º C) or at 140º F (60º C)

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Temperature Setting

 

 

98º F (37º C)

 

 

 

 

Weight

 

36.4 lb

46 lb

 

55 lb

 

 

(17 kg)

(21 kg)

 

(25 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency Rating

 

 

 

83.0%

 

 

 

 

Noise level

 

 

 

49 dB (A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

36 W

50 W

55 W

 

72 W

 

Electrical

Standby

 

 

2 W

 

 

 

 

Consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anti-frost Protection

74 W

100 W

 

116 W

 

By-Pass Control

 

Fixed

 

Electronic

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Gas Supply

Natural Gas

 

 

5.0 inch W.C.

 

 

 

 

Pressure

Propane

 

 

8.0 inch W.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Gas Supply

Natural Gas

 

 

10.5 inch W.C.

 

 

 

 

Pressure

Propane

 

 

13.5 inch W.C.

 

 

 

 

 

 

 

 

 

 

 

 

Type of Appliance

 

Temperature controlled continuous flow gas hot water system.

 

Operation

 

With or without temperature controls, mounted in kitchen, bathroom, etc.

 

 

 

Approved Gas Type

 

Natural Gas or Propane - Ensure unit matches gas type it's being installed on.

 

 

 

 

 

 

 

Connections

 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

 

 

Direct Electronic Ignition

 

 

 

 

 

 

 

 

 

 

Electric Connections

 

Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)

Water Temperature Control

 

Simulation Feedforward and Feedback.

 

 

 

 

 

 

 

 

 

 

Water Supply Pressure

 

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)

Maximum Water Supply Pressure

 

 

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Control Cable

 

Non-Polarized Two Core Cable (Minimum 22 AWG)

 

 

 

 

 

 

 

 

 

 

*Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

**for commercial and hydronic applications requiring higher temperatures.

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.