State Regulations

NOTICE BEFORE INSTALLATION

Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit.

IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL

OBSTRUCTIONS".

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

40

Manual - Rinnai Condensing Water Heaters

Page 40
Image 40
Rinnai RC98I, RC98E, RC80I, RC80E installation manual State Regulations, Important In the State of Massachusetts 248 CMR 4.00

RC80E, RC80I, RC98E, RC98I specifications

The Rinnai RC80E, RC98I, RC98E, and RC80I are high-efficiency tankless water heaters that exemplify leading-edge technology and engineering. Designed to meet the demands of modern households, these units provide continuous hot water while offering energy savings and compact sizes.

Starting with the RC80E, this model features a maximum flow rate of 8 gallons per minute, making it suitable for smaller homes or multi-family settings. It incorporates Rinnai's Circ-Logic technology, allowing homeowners to customize their hot water recirculation. This means users can schedule hot water availability, ensuring comfort while minimizing water waste.

The RC98I and RC98E models elevate performance, boasting a maximum flow rate of 9.8 gallons per minute. The "I" in RC98I stands for internal, indicating its built-in temperature control and Wi-Fi connectivity options. This allows for remote monitoring and control via a smartphone app, enhancing user convenience. In contrast, the "E" in RC98E indicates it has an external setting, providing flexibility for homeowners seeking installation options that cater to their specific needs.

All four models feature Rinnai’s condensing technology, which utilizes a dual heat exchanger design for superior efficiency. This not only lowers energy costs but also reduces CO2 emissions, aligning with eco-friendly standards. Additionally, they operate at an impressive Uniform Energy Factor (UEF), which is crucial for energy-conscious homeowners.

Safety is a significant consideration in Rinnai’s design philosophy. The RC80E, RC98I, RC98E, and RC80I come equipped with multiple safety features, including overheating protection and venting safeguards, ensuring peace of mind during operation. Their compact size allows for versatility in installation, fitting into tight spaces and freeing up valuable room in your home.

Moreover, these water heaters are designed for longevity, featuring a durable construction that resists corrosion. Rinnai's commitment to quality is evident in their extensive warranty, proving their confidence in the product’s reliability.

In summary, the Rinnai RC80E, RC98I, RC98E, and RC80I units represent a blend of advanced technology, efficiency, and convenience. With significant flow rates, innovative features like Circ-Logic and Wi-Fi compatibility, as well as robust safety measures, they are an excellent choice for any homeowner looking to enhance their hot water experience while promoting energy efficiency.