Rinnai RC98E, RC98I Clearances from Appliance, Attachment of the Water Heater, to Combustibles

Models: RC80E RC80I RC98E RC98I

1 64
Download 64 pages 29.23 Kb
Page 17
Image 17
Clearances from Appliance

Clearances from Appliance

 

RC80i, RC98i

 

RC80e, RC98e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to Combustibles

to Non- Combustibles

 

 

to Combustibles

to Non- Combustibles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of

 

6 inches *

2 inches *

 

Top of

12 inches

2 inches

to side

 

Heater

 

(152 mm)

(51 mm)

 

Heater

(305 mm)

(51 mm)

 

Back of

 

0 (zero)

0 (zero)

 

Back of

0 (zero)

0 (zero)

 

 

Heater

 

 

 

 

Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front of

 

6 inches

6 inches

 

Front

24 inches

0 (zero)

 

 

 

 

 

 

Heater

 

(152 mm)

(152 mm)

 

(Panel)

(610 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to floor/ground

Sides of

 

2 inches

1/2 inch

 

Front

24 inches

24 inches

Heater

 

(51 mm)

(13 mm)

 

(Exhaust)

(610 mm)

(610 mm)

 

 

Ground

 

12 inches

12 inches

 

Sides of

6 inches

1/8 inch

 

 

 

 

(305 mm)

(305 mm)

 

Heater

(152 mm)

(3.2 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Vent

 

0 (zero)

0 (zero)

 

Ground

12 inches

2 inches

 

 

 

 

 

 

(305 mm)

(51 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Zero inches from vent components and condensate drain line. The clearance for servicing is 24 inches in front of the water heater. For closet installation: clearance is 6 inches (152 mm) from the front.

to top

to front

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

NOTE: Rinnai water heaters should be installed in an upright position. Do not install upside down or on its side.

wall installation

brackets

Manual - Rinnai Condensing Water Heaters

17

Page 17
Image 17
Rinnai RC98E, RC98I, RC80I Clearances from Appliance, Attachment of the Water Heater, to Combustibles, to Non- Combustibles