Rinnai REU-VA3237FFU Clearances from Appliance, Attachment of the Water Heater, to Combustibles

Models: REU-VA3237FFU

1 44
Download 44 pages 2.19 Kb
Page 18
Image 18
Clearances from Appliance

Clearances from Appliance

 

to Combustibles

to Non-

 

 

Combustibles

 

 

 

 

 

 

 

 

 

 

 

 

R50LSi

 

R50LSi

 

 

 

R75LSi

R98LSi

R75LSi

R98LSi

 

 

R94LSi

 

R94LSi

 

 

 

 

 

 

 

 

Top of

6 inches

12 inches

2 inches

2 inche

 

Heater

(152 mm)

(305 mm)

(51 mm)

(51 mm)

to side

 

 

 

 

 

Back of

0 (zero)

0 (zero)

0 (zero)

0 (zero)

 

Heater

 

 

 

 

 

 

 

 

 

 

 

Front of

6 inches

24 inches

6 inches

24 inche

 

Heater

(152 mm)

(610 mm)

(152 mm)

(610 mm)

 

 

 

 

 

 

 

Sides of

2 inches

2 inches

1/2 inches

1/2 inches

 

Heater

(51 mm)

(51 mm)

(13 mm)

(13 mm)

 

 

 

 

 

 

 

Floor/

12 inches

12 inches

12 inches

2 inche

 

Ground

(305 mm)

(305 mm)

(305 mm)

(51 mm)

to floor/ground

 

 

 

 

 

Vent

0 (zero)

4 inches *

0 (zero)

0 (zero)

 

 

 

 

 

 

 

to top

to front

* 4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area.

Every vent connection must be accessible for inspection, cleaning, and replacement.

The clearance for servicing is 24 inches in front of the water heater

For closet installation: R50LSi, R75LSi, R94LSi: clearance is 6 inches (152 mm) from the front. R98LSi: clearance is 24 inches (610 mm) from the front.

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

wall installation

brackets

18

VA Series Indoor LS Manual

Page 18
Image 18
Rinnai REU-VA3237FFU Clearances from Appliance, Attachment of the Water Heater, to Combustibles, to Non, to side