Rinnai REU-VA3237FFU installation manual Maximum Vent Length

Models: REU-VA3237FFU

1 44
Download 44 pages 2.19 Kb
Page 27
Image 27
Maximum Vent Length

Maximum Vent Length

1.Determine the number of 90 degree elbows in the vent system. (Two 45 degree elbows count as one 90 degree elbow. On the R98 models each one foot of semi rigid flex duct used in the air intake length is equivalent to one 90 degree elbow.)

2.Refer to the table to find the maximum vent length based on the number of elbows.

3.Follow the applicable note.

Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual length is greater than 15 ft (4.6 m) then move dip switch no. 1 (SW1) to OFF.

Number of 90º Elbows

0

1

2

3

4

5

6

 

 

 

 

 

 

 

41 ft 1

35 ft 2

29 ft 3

23 ft 4

17 ft 4

11 ft 4

5 ft 4

(12.5 m)

(10.7 m)

(8.8 m)

(7.0 m)

(5.2 m)

(3.4 m)

(1.5 m)

 

 

 

 

 

 

 

1 If the length is greater than 21 ft (6.4 m) then move

dip switch no. 1 (SW1) to OFF.

Notes 1 2 3 4

2If the length is greater than 15 ft (4.6 m) then move dip switch no. 1 (SW1) to OFF.

3If the length is greater than 9 ft (2.7 m) then move dip switch no. 1 (SW1) to OFF.

4Move dip switch no. 1 (SW1) to OFF.

Switch No.

Manual background ON

O1

F

F 2

3

4

5

6

7

8

VA Series Indoor LS Manual

27

Page 27
Image 27
Rinnai REU-VA3237FFU installation manual Maximum Vent Length