Dip Switch Settings
Central Timer | Stand Alone |
Control | Control |
off on | off on |
1
2
3
4
1Computer Programming
2Computer Programming
3Central Control System
4Emergency Cut Off
If controlled by a central timer, dip switch 3 must be in the ON position.
To use a time clock you will also require a transformer and sub PCB available from Rinnai.
When a time clock is used the appliance On/Off button will not operate.
If Emergency cutoff loses signal unit will stop.
Emergency Cut Off can not be used with
Central Control System.
Fault Codes
| HI | Overheat | Blocked Flue Terminal |
|
|
| Switch | Blocked Air Filter |
|
|
|
| Power Failure |
|
|
|
| Warm Air Obstruction |
|
|
|
| Gas Type |
|
|
|
| Gas Pressure |
|
|
|
| Convection Fan coil resistance |
|
|
|
| PCB voltage to Convection Fan |
|
|
|
| PCB voltage to Overheat Circuit |
|
|
|
| Thermal Fuse Resistance |
|
|
|
| Overheat Switch Resistance |
|
| CI | Room Temp | Room Temp Thermistor Resistance |
|
|
| Sensor Faulty |
|
|
| C2 | Overheat Temp | Overheat Thermistor Resistance |
|
|
| Sensor Faulty |
|
|
| H6 | Overheat | Thermal Fuse |
|
| dI | Sparker Failure | PCB |
|
|
|
| Sparker input voltage |
|
|
|
| Spark Gap |
|
|
| No Ignition | Flame Rod carboned up |
|
| bI & Com- |
| PCB |
|
|
| Blocked burner ports |
| |
| bustion Lamp |
|
| |
|
| Blocked Flue Terminal |
| |
|
|
|
| |
|
|
| Gas Type |
|
|
|
| Combustion Fan |
|
|
|
| Gas Pressure |
|
| EO | Communication | PCB |
|
|
| Error (Ghost | Flame Sensor |
|
|
| Flame) | Sparker |
|
| b3 + Com- | Flame Failure | Physical Blockages |
|
| bustion Lamp |
| Flame Rod |
|
| n2 | Air Proving | Blocked Flue |
|
|
| Device | Faulty PCB |
|
|
|
| Combustion Fan |
|
|
|
| Kinked/disconnected air tube |
|
|
|
| Heat Exchanger Blocked |
|
|
|
| Air Proving Senser |
|
| n1 | On/Off Button | Check On/Off switch |
|
|
| sub PCB |
| |
|
| Faulty |
| |
|
| PCB |
| |
|
|
|
|