COMBAT® UHA UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL
14.2 Burner Compartment
The burner compartment is a sealed compartment. Following any work,
Burner compartment
cover
Flame probe
Viewing port
for flame probe
Remove flexible
air duct from spigot
Ignition electrode
NOTE: Flexible duct only applies
for models UHAS.
Viewing port
for ignition electrode
Remove
access plate Rubber Seal
Remove screws and pull off burner cover
14.2.1 Burner Injectors
Ensure gas tight fitting of injectors.
Ensure correct alignment with burners.
Ensure all pipe joints are gas tight.
|
| UHA[S] | UHA[S] | UHA[S] | UHA[S] | UHA[S] | UHA[S] | UHA[S] | UHA[S] |
MODEL |
| 150 | 175 | 200 | 225 | 250 | 300 | 350 | 400 |
|
|
|
|
|
|
|
|
|
|
Orifice Quantity |
| 7 | 8 | 9 | 10 | 11 | 12 | 14 | 14 |
|
|
|
|
|
|
|
|
|
|
Natural Gas (G20) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Orifice Marking |
| 43 | 43 | 2.25 mm | 2.25 mm | 2.25 mm | 40 | 40 | 40 |
|
|
|
|
|
|
|
|
|
|
P/N |
| 91930043 | 91930043 | 91930225 | 91930225 | 91930225 | 91930040 | 91930040 | 91930040 |
|
|
|
|
|
|
|
|
|
|
Propane (G31) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Orifice Marking |
| 1.35 mm | 1.35 mm | 54 | 54 | 54 | 1.45 mm | 53 | 53 |
|
|
|
|
|
|
|
|
|
|
P/N |
| 91930135 | 91930135 | 91930054 | 91930054 | 91930054 | 91930145 | 91930053 | 91930053 |
|
|
|
|
|
|
|
|
|
|