14.6 Flue Blower

SECTION 14: REPLACEMENT PARTS

14.6 Flue Blower

 

Rear Panel

 

Flue Adapter

Hole

to Flue Blower

 

screws

Vent Box

 

 

Vent Box

Outlet

Flue

screws

Adapter

 

Gasket

 

 

Flue Blower

 

Disconnect

 

electrical connections

 

at plug in tabs.

Remove screws securing outlet flange to the flue adapter.

Refit in reverse order.

 

Vent Box

 

Mounting

 

Plate

Gasket

Mounting Plate

to Vent Box

 

screws

Mounting Plate

Gasket

Air Plate

to Flue Blower

 

screws

 

Remove screws securing flue blower mounting plate to vent box.

Remove screws securing mounting plate to blower.

Refit in reverse.

Use new gaskets.

Ensure sealed joints.

Ensure mounting plate orifice is clear and not obstructed.

 

UHA[S]

UHA[S]

UHA[S]

MODEL

150 - 175

200 - 300

350 - 400

 

 

 

 

Flue Blower P/N

90710405

90710403

90710402

 

 

 

 

IT IS IMPORTANT THAT ONLY THE CORRECT FLUE BLOWER SPECIFIED FOR EACH MODEL TYPE IS USED WHEN REPLACING THESE ITEMS.

Carry out a start-up after working on or changing an flue blower. See Page 22, Section 11.