ROBERTS GORDON®
Coupling and Tube Assembly (Continued)
Tighten Slide Bar as shown below.
Correct Slide Bar
dimensions
Drive Slide Bar until tight. End of Slide Bar should be within tolerance listed below.
± 2" (5 cm)
Incorrect Slide Bar
position
Repeat A - D until all tubes are assembled.
NOTE: If Coupling is not tight, loss of vacuum can occur.
ELBOW PACKAGE CONFIGURATION
Elbow Installation
| Tube |
|
|
| Coupling |
Description | Part Number |
|
Elbow Package | 02718702 |
|
90° Elbow | 01335801 |
|
Coupling | 01312700 | 90° Elbow |
Reflector End Cap | 02750800 |
|
Reflector Joint Piece | 02750900 |
|
91107720 |
|
Elbow Installation (continued)
Tube |
Coupling |
© 2004
APPLICATION S, ENGI NEERING AND DETAI LED GUID ANCE ON SYSTEMS DESIGN, INSTALLATI ON AND PRODUCT PERFORMANCE IS AVAI LABLE UPON REQUEST. ROBERTS GORDON® PRODUCTS ARE TO BE INSTALLED ONLY IN ACCORDANCE WI TH LOCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIED I N THE I NSTALLATION AND SERVICE OF