ROBERTS GORDON® CRV-SE RI ES SUBMI TT AL SHE ET

Reflector, U-Clip and Reflector Support Installation

The pictorial drawings of the heater construction in this Section are schematic only and provide a gen- eral guideline of where hangers, reflector supports and U-clips are to be installed.

To ensure proper expansion and contraction move- ment of the reflectors, a combination of U-clips and reflector supports are used. The positioning of reflec-

tor supports and U-clips depend on the individual installation. Use either pop rivets or sheet metal screws instead of u-clips when installing end caps and joint pieces in areas where impact and high wind may be a factor. The following rules must be observed.

1.The first reflector after the burner must be affixed in the middle of the reflector with a reflector support and tight screws.

End

First Reflector

U-Clips

Overlap must be a

6"

minimum of 6" (16 cm)

(16 cm)

2.The overlap at the first and second reflector is a slip overlap. Thereafter, every third reflector joint is a slip overlap. A slip overlap is achieved by either:

a.) both reflectors lay inside a hanger. (no reflector support needed).

b.) using a reflector support with loose screws at the reflector overlap.

 

Tight

 

Sheet Metal

Wire Form

Screw

Reflector Support

Strap

Option B

Slip Overlap Reflector

Reflector

Support

Loose screws loosened 1/16" to allow slippage.

Option A

Slip Overlap

3.The remaining reflector overlaps require a non-slip overlap connection. To affix the reflectors together in a non-slip overlap either:

a.) use reflector support and tight screws.

b.) if both reflectors lay inside a hanger, u-clips or sheet metal screws may be used.

This section of three reflectors joined together must be affixed to the tube with at least one reflector support with tight screws.

Description

Part Number

Reflector Support Package

03050010

Wire Form

91908004

Reflector Support Strap

03050000

Screw #8 x 3/4

94320812

U-Clip Package

91107720

Reflector End Cap

027508XX

Option A

Non-Slip Overlap

Reflector

Tight

screws

Option B

Non-Slip Overlap

U-Clip

(2 clips per

non-slip overlap inside a hanger)

© 2004 Roberts-GordonBEFORE IN STALLATI ON AND OPER ATI ON OF HEATI NG EQUIPMENT, READ AND U NDERSTAND THE INSTALLATION, OPERATIO N AND SERVICE MANUAL .

APPLICATION S, ENGI NEERING AND DETAI LED GUID ANCE ON SYSTEMS DESIGN, INSTALLATI ON AND PRODUCT PERFORMANCE IS AVAI LABLE UPON REQUEST. ROBERTS GORDON® PRODUCTS ARE TO BE INSTALLED ONLY IN ACCORDANCE WI TH LOCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIED I N THE I NSTALLATION AND SERVICE OF GAS-FIRED HEATING EQUI PMENT.

Page 18
Image 18
Roberts Gorden CRV-Series service manual Reflector, U-Clip and Reflector Support Installation

CRV-Series specifications

The Roberts Gordon CRV-Series is a revolutionary line of infrared heating systems designed to provide efficient and effective solutions for a variety of industrial and commercial applications. With an emphasis on energy efficiency, performance, and reliability, the CRV-Series stands out as a preferred choice among business owners looking to optimize their heating solutions.

One of the main features of the CRV-Series is its innovative heating technology. The systems utilize infrared radiation to directly warm objects and individuals in a space, rather than heating the air. This results in faster heating times and a more comfortable environment, as it reduces heat loss and minimizes the need to overly heat the air itself. Consequently, users enjoy lower energy bills and improved comfort levels.

The CRV-Series is available in various configurations, allowing for versatility in installation and use. The modular design means that units can be easily adapted to suit different space requirements, whether in warehouses, manufacturing plants, or retail environments. This adaptability is complemented by a range of heating capacities, ensuring that businesses can find a model that fits their unique needs.

Another key characteristic of the CRV-Series is its robust construction. Built with high-quality materials, the systems are designed to withstand the rigors of industrial settings. This durability contributes to their long operational lifespan, reducing the need for frequent replacements and minimizing downtime.

Safety is also a paramount concern addressed by the CRV-Series. The systems are equipped with advanced safety features such as flame detection, automatic shut-off valves, and over-temperature protection. These features not only ensure safe operations but also provide peace of mind to users.

In terms of control and efficiency, the CRV-Series is compatible with advanced control systems that enable precise temperature regulation. This capability allows businesses to tailor their heating operations to match production schedules or occupancy levels, further enhancing energy savings.

Overall, the Roberts Gordon CRV-Series represents a blend of innovative technology, energy efficiency, and durability tailored for today's industrial and commercial environments. With its direct heating capabilities and robust features, it stands as a leading choice for businesses looking to improve their heating strategies while minimizing costs and environmental impact. Through its commitment to quality and performance, Roberts Gordon continues to set the standard in infrared heating technology with the CRV-Series.