TROUBLE-S

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

Symptom

Diagnosis

Remedy

 

 

 

 

 

 

 

 

 

 

Speaker Output

Input gain signal for

Readjust input gains of

 

 

Low or Distorted

amplifier is incorrectly

amplifier.

 

 

 

set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source unit output too

Check system with known

 

 

 

low or source unit has

working source and repair

 

 

 

no output.

or replace original source

 

 

 

 

as needed.

 

 

 

 

 

 

 

 

 

 

 

XCard is missing or not

Check XCard position and

 

 

 

placed properly in cross-

repair or replace as neces-

 

 

 

over slots.

sary.

 

 

 

 

 

 

 

 

 

 

 

Low battery voltage or

Check the alternator, bat-

 

 

 

large voltage drops to

tery, fuse, and power and

 

 

 

the amplifier under load.

ground wiring. Repair as

 

 

 

 

necessary.

 

 

 

 

 

 

 

 

 

 

Amplifier Noise

Voltage spike from out-

Disconnect input signal to

 

 

(Turn-on Pop)

put of preceding compo-

amplifier and turn ampli-

 

 

nent is entering amplifier

fier on and off. If noise is

 

 

 

 

 

 

through input signal.

eliminated, connect REM

 

 

 

 

lead of amplifier to source

 

 

 

 

unit with a delay turn-on

 

 

 

 

module.

 

 

 

 

 

 

 

 

 

 

 

Voltage spike from remote

Use a different 12 volt

 

 

 

turn-on lead is entering

source for REM lead of

 

 

 

through REM input termi-

amplifier. (i.e., battery di-

 

 

 

nal.

rect) If noise is eliminated,

 

 

 

 

use a relay to isolate am-

 

 

 

 

plifier from noisy turn-on

 

 

 

 

output.

 

 

 

 

 

 

 

 

 

 

– 27 –

Page 30
Image 30
Rockford Fosgate 40X2 manual Symptom Diagnosis Remedy, Speaker Output, Low or Distorted, Amplifier Noise