US I N G T H E XCARD
The crossover functions are controlled through the use of an XCard and can be set for
|
|
|
|
|
|
|
|
➝LP | HP➝ |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
➝HP |
|
|
|
| ||
LP➝ |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Full Range
FULL ↕
CUSTOMIZING THE XCARD
The crossover point can be altered by changing the 4 resistor values. Use the following formula to select the appropriate resistor value to be placed on the XCard.
3386 | = R (in kΩ) for .047μf cap |
fo |
|
7234 | = R (in kΩ) for .022μf cap |
fo |
|
AO
DP
VE
AR
A N T C I E O
D N
The actual formula is:
R = | 1 |
| |
2πfoc | |||
| |||
Where: R = Ω |
|
|
| Crossover Card | FULLC2 |
| ||
C1 | R1 | C2 | High Pass | R1 | R2 | ||
R2 | C1 | ||||||
|
|
| Low Pass |
|
|
|
Full Range
fo = desired crossover frequency c = capacitor in farads
ex: .047 x
– 13 –