Roland M-48 owner manual Troubleshooting

Models: M-48

1 36
Download 36 pages 4.07 Kb
Page 34
Image 34

Troubleshooting

Symptom

Cause

 

The M-48’s output has been muted by an operation from the M-400 or computer. To cancel the mute

 

using the M-48, press any of the top panel buttons.

 

The REAC connection has not been established (p. 20). Check whether there might be a problem

No sound.

with the REAC cable or connections.

The settings for the source/level or Source Assign, made on either the M-400 or on a computer, are

 

 

inappropriate (p. 21–25).

 

In situations where an M-400 or a computer is unavailable, the settings for the source/level or Source

 

Assign can be modified by means of a Recall from memory (p. 31) or a Factory Reset (p. 31).

 

 

Can’t adjust the audio that you want to

The source you’re trying to adjust is not assigned to a group.

monitor.

 

 

 

Pressing the [SOLO] button does not do

The Solo mode setting has been changed from the M-400 or computer (p. 22).

what you expect.

 

 

 

Can’t perform recall/store operations.

Recall/store operations on the M-48 have been disabled from the M-400 or computer.

 

 

The volume level of the instrument

You are using a connection cable that contains a built-in resistor. Use a connection cable that does

connected to the AUX IN L/R jack is too

not contain a resistor.

low.

 

 

 

For EU Countries

34

Page 34