Roland MP-500 owner manual Midi Implementation Chart

Models: MP-500

1 44
Download 44 pages 12.76 Kb
Page 39
Image 39

MIDI

Implementation

Chart

DIGITAL PIANO

Model MP-500

MIDI Implementation Chart

Date : Aug. 1, 2002

Version : 1.00

 

Function...

 

Transmitted

 

 

Recognized

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Basic

Default

1

 

 

1

 

 

Channel

Changed

1–16

 

1–16

 

 

 

 

 

 

 

 

Default

Mode 1

 

Mode 1

 

Mode

Messages

x

 

 

OMNI ON/OFF

 

 

Altered

**************

 

 

 

 

 

 

 

 

 

 

Note

 

15–113

 

0–127

 

Number :

True Voice

**************

 

15–113

 

 

 

 

 

 

 

 

 

Velocity

Note ON

O

 

 

O

 

 

Note OFF

x

8n v=64

 

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After

Key's

x

 

 

x

 

 

Touch

Ch's

x

 

 

x

 

 

 

 

 

 

 

 

 

 

Pitch Bend

 

x

 

 

x

 

 

 

 

 

 

 

 

 

 

 

6, 38

O

*1

 

O

*1

Data entry

 

7

x

 

 

O

*1 *2

Volume

 

11

x

*1

 

O

*1 *2

Expression

Control

64

O

 

O

*1 *2

Hold 1

66

O

 

 

O

*1 *2

Sostenuto

Change

 

 

67

 

 

O

*1 *2

Soft

O

*1

 

 

91

 

O

*1

Effect1 depth (Reverb)

 

O

*1

 

 

93

 

O

*1

Effect3 depth (Chorus)

 

O

*1

 

 

100, 101

 

O

*1

RPN LSB, MSB

 

O

*1

 

 

 

 

 

 

 

 

 

 

 

 

 

Prog

 

O (0–44) *1

 

O (0–127) *1

 

Change

: True Number

**************

 

0–44

 

 

 

 

 

 

 

 

System Exclusive

O

 

 

O

 

 

 

 

 

 

 

 

 

 

System

: Song Pos

x

 

 

x

 

 

: Song Sel

x

 

 

x

 

 

Common

 

 

 

 

: Tune

x

 

 

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System

: Clock

x

 

 

x

 

 

Real Time

: Commands

x

 

 

x

 

 

 

 

 

 

 

 

 

 

 

: All sound off

x

 

 

x

 

 

Aux

: Reset all controllers

x

 

 

O

 

 

: Local ON/OFF

x

 

 

O

 

 

Message

: All Notes OFF

x

 

 

O (123–127)

 

 

: Active Sense

O

 

 

O

 

 

 

: System Reset

x

 

 

x

 

 

Notes

 

*1

O x is selectable.

 

 

 

 

 

*2

This message can affect only MIDI notes.

 

 

 

 

 

 

 

Mode 1 : OMNI ON, POLY

Mode 2 : OMNI ON, MONO

 

 

O : Yes

Mode 3 : OMNI OFF, POLY

Mode 4 : OMNI OFF, MONO

 

 

X : No

*A separate publication titled “MIDI Implementation” is also available. It provides complete details concerning the way MIDI has been implemented on this unit. If you should require this publication (such as when you intend to carry out byte-level programming), please contact the nearest Roland Service Center or authorized Roland distributor.

39

Page 39
Image 39
Roland MP-500 owner manual Midi Implementation Chart