About the Protection Circuits
The
1. Thermal Protection Circuit—Protects the Amp
Speaker output is cut if the temperature of the amp's heat sink exceeds 100˚C. Stop operating the equipment for a short while to allow the heat to dissipate sufficiently. In addition, check the setup of the
(For more information on
*The unit automatically restarts when the temperature of the heat sink falls. However, if the overheating protection circuit is activated again, check to make sure that the operating environment and the speakers connected to the amp output connectors conform to the
2. DC Detection Circuit—Protects the Speakers
Whenever DC (direct current) is generated in the output sent to the speakers, the output is cut off, protecting the speakers.
→The
3. Muting Circuit—Protects the Speakers
When the power is switched on, output to the speakers is cut for a few seconds, thereby protecting the speakers from the sudden noise that occurs when the power is switched on.
12