User selectable settings

(PC and SUN models)

Dipswitch SW1 on the Remote Units PCB has four switches that allow you to change settings from their factory set values. SW1 settings only apply to the CrystalView Dual model. If your model is a Single version, switches 1-4 should all be set to the factory settings.

(Factory settings are in BOLD.)

Switch

Function

Left (OFF)

Right (ON)

1

Privacy mode

Enabled

Disables

 

 

 

 

2

Lockout time

15 sec.

2 sec.

 

 

 

 

3

Activation method

Kbd. or mouse

Keyboard

 

 

 

 

4

Scroll lock key

Normal keyboard

Commands to

 

 

function

CrystalView

 

 

 

 

Table 1. User settings (PC/SUN models)

Note: Switch #1 on, remote monitor will not blank in Private mode

(PC-Serial/Audio model)

The CrystalView models with the Serial/Audio option have Dipswitch SW1 switches 1, 3, and 4 inoperable. Dipswitch 2 sets either the right or left control key to be the key to initiate commands to the CrystalView. (Press and release the control key, then enter the command to send to the CrystalView.) See Figure 5 for SW1 setting and location.

Factory settings are in BOLD

Switch

Function

Left (OFF)

Right (ON)

1

N/A

N/A

N/A

 

 

 

 

2

Command key

Right control key

Left control key

 

 

 

 

3

N/A

N/A

N/A

 

 

 

 

4

N/A

N/A

N/A

 

 

 

 

Table 2. User settings (PC-Serial/Audio model)

(MINI model)

For normal scroll lock key operation set Dipswitch #2 on the bottom of the Remote Unit to “ON” (default = “Off”).

CRYSTALVIEW INSTALLATION AND OPERATIONS MANUAL

17

 

Page 21
Image 21
Rose electronic CrystalView TWISTED PAIR KVM EXTENDER User selectable settings PC and SUN models, Enabled, Sec, Keyboard