RSP-1066Surround Sound Processor

28

tal and/or DTS surround modes. In other sur- round modes, there is no LFE channel and the subwoofer will only reproduce redirected bass from the other channels, which is not as likely to tax the subwoofer.

The CROSSOVER setting activates a low-pass filter for the subwoofer and a corresponding high-pass filter for all SMALL speakers in the system at the selected frequency. To adjust the crossover frequency, highlight the CROSSOVER line using the UP/DOWN buttons. Then, use the +/– buttons to chose one of the following options: OFF, 40Hz, 60Hz, 80Hz, 100Hz, or 120Hz. The 80Hz or 100Hz crossover points are the most common in home theater systems. However, your best setting depends on the specific speakers in your system.

NOTE: The OFF setting sends a full-range sig- nal to your subwoofer so that you can use its built-in low-pass filter. With the OFF setting, a 100 Hz high-pass filter is activated for all SMALL speakers in the system.

To return to the MAIN menu, press the EN- TER button. Press the MENU key on the remote to cancel the display and return to normal operation.

OTHER OPTIONS Menu

OTHER OPTIONS

RECORD: CD

DYNAMIC: Max

MULTI INPUT: Off

CINEMA EQ: Off

POWER: Direct

OSD: On

LANGUAGE: ENGLISH

ENT

KEY=MAIN MENU

UP KEY=up

+/–

KEY=change

DWN KEY=down

This menu, accessed from the MAIN menu, provides access to several miscellaneous set- tings as follows:

RECORD: Select a signal for the record out- puts by choosing one of the input sources.

DYNAMIC: steps through the three dynamic range settings available in digital modes:

MAX (no compression/full dynamic range)

MID (moderate compression)

MIN (full compression/minimum dynamic range).

MULTI INPUT: determines whether the MULTI channel input is turned ON or OFF.

CINEMA EQ: determines if a special equal- ization setting is turned ON or OFF. This equal- ization may be desirable for playback of movie source material to compensate for the acous- tic differences between a commercial cinema and a home theater environment. The CIN- EMA EQ setting can also be changed using the FILTER button on the remote.

POWER: This setting determines how the RSP-1066 powers up. With the default DIRECT setting, the unit is fully activated when AC power is applied and the front-panel POWER button is pressed in; however, it may be put in STANDBY mode using the remote POWER button. With the STANDBY setting, the unit pow- ers up in standby mode when AC is applied and the front-panel POWER button is in the ON position. The unit must be activated us- ing the remote control POWER button. In AL- WAYS-ON mode, the unit remains fully active whenever AC is present and the front-panel POWER button is pressed in; the remote POWER button is disabled and the unit can- not be put in standby mode.

OSD: Determines whether the ON-SCREEN DISPLAYS are shown on your TV monitor dur- ing operation.

LANGUAGE: Selects one of the several lan- guages for all of the ON-SCREEN MENUS.

Change settings on the OTHER OPTIONS menu by highlighting the desired line using the UP/ DOWN buttons and using the +/– buttons to step through the available settings. To return to the MAIN menu, press the ENTER button. Press the MENU key on the remote to cancel the display and return to normal operation.

DEFAULT SETUP Menu

DEFAULT SETUP

FACTORY DEFAULT: No

USER DEFAULT: No

USER DEFAULT SET: No

ENT

KEY=MAIN MENU

UP KEY=up

+/–

KEY=change

DWN KEY=down

DEFAULT SETUP

FACTORY DEFAULT: Yes

USER DEFAULT: No

USER DEFAULT SET: No

ENT

KEY=Exec.

UP KEY=up

+/–

KEY=change

DWN KEY=down

The DEFAULT SETUP menu provides access to three functions:

Restoring all features and settings to the original FACTORY DEFAULT settings.

Memorizing a custom group of settings as a USER DEFAULT.

Activating the USER DEFAULT settings.

To restore the FACTORY DEFAULT set-

tings: Place the highlight on the FACTORY DEFAULT line using the UP/DOWN buttons and use the +/– buttons to change the setting to YES. The screen will change to a confirma- tion screen. Press the ENTER button to proceed with resetting the FACTORY DEFAULT settings. The unit will power off and then on, with the factory settings restored. To return to the MAIN menu without resetting the FACTORY DEFAULT settings, change the entry to NO and press the ENTER button.

NOTE: Resetting to factory default settings will erase all stored settings including delay set- tings, speaker settings, balance settings, in- put settings and more. You will lose ALL system configuration settings. Be certain that you wish to do so before resetting the factory defaults.

To save USER DEFAULT settings: Many of the current configuration settings can be stored as a USER DEFAULT, which can be activated at any time from this menu screen. To save the current settings as a USER DEFAULT Place the highlight on the USER DEFAULT SET line using the UP/DOWN buttons and use the

Page 28
Image 28
Rotel RSP-1066 owner manual Other Options Menu, Default Setup Menu, To restore the Factory Default set