4.Defective Main PCB.
a. Replace the PCB Main.
2.3Rollers Not Running
CAUSES
1.No power to the unit.
2.The main switch is close.
3.Opened safety cover.
4.Film is jammed on the rollers.
5.Disconnected motor wire.
6.Defective main motor.
7.Defective main PCB.
MEASURES
1.No power to the unit.
a. Make sure the power plug is connected to the proper source of outlet
2.The main switch is close.
Main Switch
3.Opened safety cover.
a. Close the safety cover and double check to insure that the safety cover switch is engaged.
Note: By closing the safety cover, it engages the safety cover switch.
5