4.5 Console Port Wiring
A RS232 console port for configuration and management of the device is located on the LED display module shown in Figure 13. This port is intended to be a temporary connection during initial configuration or troubleshooting and allows for direct access to the
Figure 13: Console port location on display board | Figure 14: M2000 Console cable |
For user reference, the console cable
RuggedCom RS232 over RJ45 pin-out specification
Signal Name (PC is DTE) | DB9- Female | RJ45 Male |
DCD – Carrier detect | 1 | 2 |
RxD – Receive data (to DTE) | 2 | 5 |
TxD – Transmit data (from DTE) | 3 | 6 |
DTR – Data terminal ready | 4 | 3 |
Signal GND | 5 | 4 |
DSR – Data set ready | 6 | 1* |
RTS – Ready to send | 7 | 8 |
CTS – Clear to send | 8 | 7 |
RI – Ring Indicator | 9 | 1* |
Table 4: RS232 over RJ45 console cable
After initial configuration, the RuggedSwitch device can be configured via a number of new mechanisms such as Telnet, and the
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m (6.5 ft) in length.
19