RS-232 COMMUNICATIONS AND COMMANDS

Baud rate: 19200 (fixed)

Bits: 8

No Parity

All protocol in ASCII format

RS-232 input connector pin numbers:

TxD= Pin# 2, RxD= Pin# 3, GnD= Pin# 5

Command format (single command): command value (i.e. brightness 100).

NOTE: A space (not an underscore) or comma may be used between the command and its value.

Command string format: command, command value, command etc. (i.e. COMPOSITE, BRIGHTNESS 100, ANAMORPHIC, <CR>)

NOTE: In between commands, a comma or space may be used

NOTE: A carriage return must be used after each command or string.

Other notes:

For command strings, a maximum of 255 characters can be used in a single string.

PARAMETER min/max refers to a function’s minimum and maximum value range. Inputting values above or below their range may cause unpredictable (but not fatal) results.

22

Page 23
Image 23
Runco pmn manual RS-232 Communications and Commands