PUNCHDOWN TERMINALS
Figure 11 – Punchdown Terminal on CA-KP.2 and CA-LCD
2 1 3 6 5 4 8 7
IR | GND | +12V | CH SEL | SEL3 | SEL1 | BAL | VOL |
The
Press wires into punchdown terminal with punchdown tool as shown in Figure 12.
Figure 12 – Punching Down Wires
Punchdown
Tool
IR
IR | GND | +12V | CH SEL | SEL3 | SEL1 | BAL | VOL |
2 | 1 | 3 | 6 | 5 | 4 | 8 | 7 |
Connector on
INSTALLING KEYPADS
INSTALLING THE KEYPADS
•The best infrared remote performance is achieved with the keypad away from any direct sunlight. Also consider convenience when choosing a location.
•Choose a place that is easily seen from the position where a person is most likely to be located.
•Check whether or not you can route the wire to the loca- tion you have chosen.
•Purchase
•If you are installing the optional DSC keypad you will need to use a
•If you feel uncomfortable cutting into your walls and running wire through the walls, seek help from a profes- sional installer or an electrician.
•Route the wire to the junction box from the CA location.
•If using 22 AWG wire, connect each wire to the correct position 1 thru 8 using the included punchdown tool. Refer to List 5.
•If using
•Mount the keypad in the junction box and attach the Decora plate.
•The
•Repeat the above steps until all keypads are installed.
BROWN | GREEN | ORANGE | BLUE |
22 AWG wire