ELECTRICAL
EXTENSION CORDS
Use only
**Ampere rating (on product data plate)
Cord Length |
| Wire Size (A.W.G.) |
|
| |||
|
|
|
|
|
|
|
|
25' | 16 | 16 | 16 | 16 | 14 | 14 | |
|
|
|
|
|
|
|
|
50' | 16 | 16 | 16 | 14 | 14 | 12 | |
|
|
|
|
|
|
|
|
100' | 16 | 16 | 14 | 12 | 10 | — |
**Used on 12 gauge - 20 amp circuit. NOTE: AWG = American Wire Gauge
When working with the product outdoors, use an extension cord that is designed for outside use. This is indicated by the letters “WA” on the cord’s jacket.
Before using an extension cord, inspect it for loose or exposed wires and cut or worn insulation.
WARNING:
Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, products or other obstructions while you are working with a power product. Failure to do so can result in serious personal injury.
WARNING:
Check extension cords before each use. If damaged replace immediately. Never use product with a damaged cord since touching the damaged area could cause elec- trical shock resulting in serious injury.
ELECTRICAL CONNECTION
This product should be connected to a power supply that is 120 volts, 60 Hz, AC only (normal household current). Do not operate this product on direct current (DC). A substantial voltage drop will cause a loss of power and the motor will overheat. If the router table does not operate when plugged into an outlet, double check the power supply.
SPEED AND WIRING
The
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding pro- vides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with an electric cord having an
Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician. Improper connection of the
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately.
This product is intended for use on a circuit that has an outlet like the one shown in figure 1. It also has a grounding pin like the one shown.
GROUNDING |
|
PIN | 120 V GROUNDED OUTLET |
| |
| Fig. 1 |
7