WarningWhen you use the DC power output jack, you have to check the standard output power of STB(SBB) and you should use the DC power within the standard output(Class 2 Wiring-5V DC/2.5A (12V DC/1.5A).

For 5V SBB, SBB load current must not exceed 2.5A.

For 12V SBB, SBB load current must not exceed 1.5A.

The initial output is 5V.

For 12V SBB, you have to change the output voltage to 12V in order to use the power.Changing the Output Voltage (Only for EU C457 26" 32" 37" 40" model)

1. Press the POWER button.

The TV is powered on.

2. Press the following remote control buttons in order.

INFO MENU 0 1 EXIT

The Hotel Option menu appea rs.

3. Press the or button to select DC Power Output.

Press the or button to select 12V or 5V.

4. Remove the power cord then plug it back in again.

The voltage change is appl ied when you turn the TV on

again after changing the I nteractive mode Option setting.

Hotel Mode ON RJP Priority AV 1
Logo Download
...
SI Vendor
Samsung
RJP Priority PC 2
Logo Display Time
...
Power On Channel 1RJP Priority HDMI 3
Power On Option Last Option
Channel Type ATV RJP AV Option AV1 Auto Source OFF
Power On Volume 10 RJP HDMI Option HDMI1
Energy Saving
Off
Min Volume 0Sub AMP Volume 6
Clone : TV to USB
Max Volume 100 Sub AMP Mode
2
Clone : USB to TV
Panel Button Lock
Unlock Local Time Manual Pan Euro MHEG OFF
Power On Source TV Time Format 12 Hour
Cloning Data Reset
OFF
Picture Menu Lock
OFF PMOLED Test
Failure
Welcome Message
Channel Editor
PMOLED Mormal Dim.
3
Edit Welcome Message
Music Mode AV
OFF
PMOLED Standby Dim.
2DC Power Out 5V
Music Mode PC
OFF
Audio Loop In
OFF
Channel Auto Store
Music Mode Comp
OFF
Menu Display
ON
Dynamic SI
OFF
Music Mode Backlight
OFF
Hotel Logo
OFF

LC452_453_457-hotel.indd 16 2010-04-12 오후 8:37:29