4. Troubleshooting

4-3. When the screen is blank (Analog)

Symptom

- LEven though the LED power turns on, the screen is blank when connecting the VGA cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Even though the LED power turns on, the screen is blank when connecting the VGA cable.

Major checkpoints

- Check the D-sub cable connections.

- Check whether the LVDS cable is connected correctly to the panel.

 

- Check whether the lamp connector of the panel is connected correctly to the IP board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN 400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IC 200

 

 

 

 

 

X 201

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R111, R114, R118

 

 

Check the signal cables and

 

 

 

 

 

 

their connections.

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is X201 oscillating correctly?

No

Check and replace the circuits

 

 

 

 

related to X201.

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

Do the RGB inputs appear at R111,

No

Check the R111, R114, and

 

 

R114, and R118?

 

 

R118 input terminals.

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

Do the Hsync and Vsync

No

 

Check the circuits related to

Diagnostics

waveforms appear at pins 32, 33 of

 

 

IC200.

 

 

IC200, respectively?

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

Do output signals appear at pins 8 to 30

No

Check the circuits related to

 

 

of CN400?

 

 

CN400.

 

 

 

Yes

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

Is DC 5V measured at pins 1, 2, and 3

Check the +5V_Panel signal

 

 

of the CN400?

 

 

and the BL_EN signal.

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check and replace the panel.

 

 

 

 

 

 

 

 

 

 

 

Caution

Make sure to disconnect the power before working on the IP board.

4-4

Page 32
Image 32
Samsung 943NWX service manual When the screen is blank Analog