4. Troubleshooting

4. Troubleshooting

4. Troubleshooting

4-1. Troubleshooting

1.Set custom mode as follows before beginning a repair.

Resolution: 1440 x 900

V-frequency: 60 Hz

2.If the screen is blank, check whether the power cord is connected correctly.

3.The circuits to check:

When the raster does not appear: The Function PCB, Main PCB, I/P PBA

When 5V is generated but a blank screen is displayed: Main PCB

When 5V is not generated: I/P PBA

4.“Press the MENU button and hold down the, “4-1. TroubleshootingManual backgroundManual backgroundManual background (Enter, Source)” button for more than five (5) seconds to return the monitor to factory mode.