Nortec MH Series installation manual 10-10, On Softstart function activated

Models: MH Series

1 40
Download 40 pages 28.61 Kb
Page 23
Image 23
On (Softstart function activated)

1.1.10 Configuring the Humidifier Maintenance Interval

Select “Maintenance” in the settings menu, then press the <Set> key. In the following dialogue set the desired maintenance interval time in hours. After the maintenance interval time has elapsed a maintenance message appears in the display and the yellow LED lights up. If the maintenance is not performed and the maintenance indication is not reset within a certain time (168 h) , an error message is triggered. Factory setting: 800 h Setting range: 100... 50000 h

Note: to determine the maintenance interval time please refer to 1.3 in section 10-40 of the installation and operating instructions for the Nortec MH.

1.1.11Activating/deactivating the softstart function

If the mats in the humidifier boxes became dry due to a operation interruption, they need a certain time until they are again moistened with water. In order to prevent too much water flows over the humidification boxes in this phase and water droplets are carried in the air flow, the amount of water can be reduced for a fixed time with the “Softstart” function.

Select “Softstart” in the settings menu, then press the <Set> key. In the modification dialogue you can activate or deactivate the softstart function. Factory setting: Off Options: Off (Softstart function deactivated)

On (Softstart function activated)

10-10

Page 19 2008-12-03

Page 23
Image 23
Nortec MH Series installation manual 10-10, On Softstart function activated