Samsung AD18B1C09 26,000Btu/h, B-unit, A-unit, Piping length and the height, E-32

Models: AD18B1C09

1 54
Download 54 pages 30.52 Kb
Page 32
Image 32
◗26,000Btu/h

PREPARING THE INSTALLATION

Deciding on Where to Install the Air Conditioner (cont.)

26,000Btu/h

Indoor unit

Outdoor unit

Power supply

Ø, V, Hz

 

AD26B1C13

UD26B1C2 1,208-230~,60

Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.

B-unit

12,500 Btu/h

25 mm (1 inch)

or more

A-unit

12,500 Btu/h

100 mm (4 inch) or more

 

600 mm (24 inch)

 

minimum

300 mm

 

(12 inch)

300 mm

minimum

(12 inch)

 

minimum

600 mm

 

(24 inch)

A

minimum

B

 

160 mm (6 inch) or more

A

(15 m (49ft. 3in) maximum)

B

(7 m (23ft) maximum)

Circuit breaker

Main power switch

(20A)

 

INDOOR UNIT

A

B

OUTDOOR UNIT

E-32

Piping length and the height.

Unit

Pipe size

MAX. piping length

MAX. height

 

 

Liquid

GAS

A

B

 

A-unit

1/4"

1/2"

15 m (49ft. 3in)

7 m (23ft)

B-unit

1/4"

1/2"

15 m (49ft. 3in)

7 m (23ft)

Page 32