PREPARING THE INSTALLATION
Deciding on Where to Install the Air Conditioner (cont.)
◗26,000Btu/h
Indoor unit
Outdoor unit | Power supply | |
Ø, V, Hz | ||
|
AD26B1C13
UD26B1C2
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
12,500 Btu/h
25 mm (1 inch)
or more
12,500 Btu/h
100 mm (4 inch) or more
| 600 mm (24 inch) |
| minimum |
300 mm |
|
(12 inch) | 300 mm |
minimum | (12 inch) |
| minimum |
600 mm |
|
(24 inch) | A |
minimum | B |
|
160 mm (6 inch) or more
A
(15 m (49ft. 3in) maximum)
B
(7 m (23ft) maximum)
Circuit breaker | Main power switch |
(20A) |
|
INDOOR UNIT |
A |
B |
OUTDOOR UNIT |
|
Piping length and the height.
Unit | Pipe size | MAX. piping length | MAX. height | ||
|
| ||||
Liquid | GAS | A | B | ||
| |||||
1/4" | 1/2" | 15 m (49ft. 3in) | 7 m (23ft) | ||
1/4" | 1/2" | 15 m (49ft. 3in) | 7 m (23ft) |