INSTALLING THE OUTDOOR UNIT

Auxiliary Circuit Breaker

Auxiliary circuit breaker should be installed near outdoor unit so that each access is possible. Main/outdoor power supply cable are connected to upper/lower terminal of auxiliary circuit breaker.

It is necessary that the conduit kit for power supply to the outdoor unit be installed between auxiliary power S/W and the outdoor unit. (the conduit kit is optional)

ENGLISH

Outdoor unit

Distribution

 

board

 

Auxiliary

 

power s/w

The designs and shape are subject to change according to the model.

Electrical Work

1The supply voltage must be the same as the rated voltage of the air conditioner.

2Prepare the power souce for exclusive use with the air conditioner.

3Use 20 amperes time delay fuse or circuit breaker.

MODEL

AD18B1C09

AD26B1C13

 

 

 

Power supply

208-230V~/60Hz

 

 

Power cable

3G AWG 14

 

 

 

Assembly cable

4G AWG 16

 

 

 

Operating current(C/H)

8.4A / 7.8A

11.4A / 11.6A

 

 

 

Starting Current

22A

31A

 

 

 

Power consumption (C/H)

1920W / 1780W

2550W / 2600W

 

 

 

When using the special NFB, use the NFB to bear the capacity of the air conditioner.