Samsung AP500PF installation manual Electricali Work, When connecting 3Phase 3wires 208 ~ 230V AC

Models: AP500PF

1 34
Download 34 pages 24.25 Kb
Page 24
Image 24
ELECTRICALI WORK

ELECTRICALI WORK

When connecting 3Phase 3wires 208 ~ 230V AC When connecting 3Phase 3wires 208 ~ 230V AC

1.Remove cover of electric box on side panel of outdoor unit.

2.Connect electric input wires (R,S,T) to each terminal (R,S,T) of the electric box on outdoor unit respectively. (Input wires are purchased by the user separately.)

3.Connect electric wires (red, white, black) to each terminal (red, white, black) on indoor and outdoor unit respectively.

R S T

Knife switch or

automatic circuit

breaker

OUTDOOR SIDE

Power terminals on the outdoor unit

R S T

Red White Black

Red

White

Black

Electric input wires

Indoor / outdoor unit

connecting wire

 

E-24