Samsung AQ12SGGB, AQ24S6GB, UQ07SBGE, UQ09SBGE, UQ12SBGE, UQ09S8GE, UQ12SGGB Solving Common Problems

Models: AQ07S8GE AQ07SBGE AQ12SGGB AQ12SGGE AQ09S8BG AQ09SBGS AQ12SBGE SH12ZSGX SH07ZS8 SH18ZS0 SH09ZS8 SH09ZS8X SH12ZSG SH07ZS8X SH24TS6 AQT24S6GE AQ18S0GE AQ18S0GB UQ12SGGE UQ07S8GE UQ12SGGB UQ09S8GE UQ12SBGE UQ09SBGE UQ07SBGE AQ24S6GB

1 28
Download 28 pages 6.19 Kb
Page 23
Image 23
Solving Common Problems

Solving Common Problems

Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call.

Problem

Explanation/Solution

 

 

The air conditioner does not operate at all

Check that the breaker used for the air conditioner is switched on.

Check that the operation indicator on the indoor unit is on;

if necessary press the Manual background (On/Off) button on the remote control.

Check whether the TIMER indicator on the indoor unit is switched on. If so:

-Wait until the switch-on time is reached and the air conditioner starts up automatically

-Cancel the timer (see pages 18 and 19 for further details)

The air conditioner does not operate with the remote control

Check that there are no obstacles between you and the indoor unit.

Check the remote control batteries.

Check that you are close enough to the indoor unit (seven meters/ yards or less).

No beep is heard when you press the Manual background (On/Off) on the remote control

Check that you are pointing the remote control at the remote control sensor in the right of the indoor unit.

Replace the remote control batteries if necessary.

The air conditioner does not cool or heat

Check that the correct operating mode has been selected (AUTO, COOL, HEAT).

The room temperature may be too low or too high.

Dust may be blocking the air filter guard; refer to page 24 for cleaning instructions.

Check that there is no obstacle in front of the outdoor unit.

When heating, the required room temperature is never reached and the air conditioner frequently stops

Check that the required temperature has been set correctly.

Increase the fan speed.

If the air flow is directed upwards, use the remote control to direct it downwards.

The fan speed does not change Check that the operating mode is set to COOL, HEAT or FAN ; in the

when you press the Manual background button AUTO mode, the fan speed changes automatically and in the DRY mode, it is set to AUTO.

The air flow direction does not Check that the air conditioner has been switched on; if necessary,

change when you press thepress the Manual background (On/Off) button on the remote control. Manual background button

The timer is not correctly triggered Check that the timer has been programmed correctly; see pages 18 and 19.

Odours are permeated in the room Air the room. during air conditioning

E-23

Page 23
Image 23
Samsung AQ12SGGB, AQ24S6GB, UQ07SBGE, UQ09SBGE, UQ12SBGE, UQ09S8GE, UQ12SGGB, UQ07S8GE, UQ12SGGE, AQ18S0GB Solving Common Problems