Performing the gas leak tests

Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate).

A C D

B

07stIn llan atio

Test part for outdoor unit

Tightening torque for body cap (Refer to the table)

Spindle

Charging

core

R-22: Diameter of the screw - 7/16-20UNF

R-410A: Diameter of the screw - 1/2-20UNF

Tightening torque for charging port cap (Refer to the table)

To check for gas leaks on the outdoor unit,

Check the valve A and B using a leak detector.

Test part for indoor unit

Before inspecting the leakage, use a torque wrench to close the cap for the service valve. (Comply with a tightening torque for each size of the diameter,and tighten the cap firmly to prevent any leakage.).

To check for any possible leakage, insert inert gas into the pipes connected to indoor/outdoor units and check the connection part of the indoor/outdoor units with soap lather or liquid for leakage test.

Outer

Tightening torque

Diameter

Body cap (N•m)

Charging port cap

(mm)

(N•m)

 

ø 6.35

20 ~ 25

 

ø 9.52

20 ~ 25

 

ø12.70

25 ~ 30

10 ~ 12

ø15.88

30 ~ 35

 

ø19.05

35 ~ 40

 

( 1 N•m = 10 kgf•cm )

To check for gas leaks on the indoor unit,

Check the flare nut C and D using a leak detector.

Leak test with nitrogen (before opening valves)

In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R-410A.

Leak test (after opening valves)

Before opening valves, discharge all the nitrogen from the system and create vacuum according to page 44~46. After opening valves, check leaks using a leak detector for refrigerant.

Pump down (before disconnecting the refrigerant connections for unit repair, removal or disposal) Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit.

This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

Shut off the liquid valve with the Allen wrench.

Turn the system on in cooling with fan operating at high velocity.

(Compressor will immediately start, provided 3 minutes have elapsed since the last stop).

After 2 minutes of operation, shut the suction valve with the same wrench.

Turn the system off and switch mains supply off.

Disconnect tubing. After disconnection, protect valves and tubing ends from dust.

Compressor damage may occur if run at a negative suction pressure.

English-47

MG_BORACAY_IB&IM_EN_DB68-05789A-00.indd 47

12/4/2015 4:48:36 PM

Page 47
Image 47
Samsung AR24KQFHCWKNMG, AR24KRFHCWKNMG, AR18KRFHCWKNMG, AR18KQFHCWKNMG manual Performing the gas leak tests, English-47

AR18KQFHCWKNMG, AR24KRFHCWKNMG, AR24KQFHCWKNMG, AR18KRFHCWKNMG specifications

Samsung has long been a frontrunner in the HVAC (Heating, Ventilation, and Air Conditioning) industry, and its innovative range of split air conditioners, including models AR18KRFHCWKNMG, AR24KQFHCWKNMG, AR24KRFHCWKNMG, and AR18KQFHCWKNMG, exemplifies the brand’s commitment to performance, efficiency, and comfort. These models serve varying room sizes and needs, making them ideal for residential and commercial spaces alike.

One of the standout features across these models is the advanced inverter technology. This technology allows the compressor to operate at variable speeds, adjusting to temperature fluctuations seamlessly. As a result, users benefit from higher energy efficiency and lower electricity bills, while also enjoying a consistent and comfortable indoor climate. The Digital Inverter technology reduces unnecessary energy consumption compared to traditional non-inverter models.

Another key feature of these air conditioners is the triple filtration system. Samsung’s air purifying filters capture dust, allergens, and harmful particles, ensuring a healthier environment. This system includes a reusable and washable filter that promotes ease of maintenance and extends the lifespan of the unit, which is ideal for users who prioritize cleanliness and air quality.

Additionally, noise reduction technology makes these models exceptionally quiet, enhancing user comfort. With operational noise levels kept to a minimum, individuals can enjoy a peaceful atmosphere whether at home or at work, making these units perfect for bedrooms and quiet environments.

These models are also equipped with Smart features, allowing remote control via a smartphone app. Users can monitor and adjust settings from virtually anywhere, adding convenience to their daily lives. The presence of one-touch controls simplifies the user experience, allowing for quick adjustments as needed.

Moreover, the sleek and modern design of the AR18KRFHCWKNMG, AR24KQFHCWKNMG, AR24KRFHCWKNMG, and AR18KQFHCWKNMG ensures that they blend well with contemporary interiors. Their aesthetic appeal, coupled with functional excellence, makes them an attractive addition to any space.

In conclusion, Samsung’s AR18KRFHCWKNMG, AR24KQFHCWKNMG, AR24KRFHCWKNMG, and AR18KQFHCWKNMG air conditioners stand out due to their innovative technologies, energy efficiency, advanced filtration systems, noise reduction capabilities, and smart functionality. These features, along with their stylish designs, make them an excellent choice for anyone looking to enhance their indoor comfort while prioritizing health and efficiency.