• The flare nuts are attached to the end of each pipe of an evaporator or a service port.

Use the nuts when connecting the pipes.

The wire assembly cable is optional. If it is not supplied, use the standard cable.

The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.

Optional accessories

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Putty 100 g (1)

Pipe Clamps A (3)

Ø6.35 mm (1)

Ø15.88 mm (1)

Insulation (1)

 

 

 

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Drain Hose,

3-wire

3-wire

Assembly Cable (1)

Assembly Cable (1)

Screws (6)

length 2 m (1)

 

 

✴✴18/24KR✴✴

✴✴18KQ✴✴

 

 

 

 

2-wire

4-wire

 

 

 

 

Assembly Cable (1)

Assembly Cable (1)

 

 

 

 

✴✴18KQ✴✴

✴✴24KQ✴✴

 

 

 

 

atio nall Inst07

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

GeneralTools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

• Thermometer

• Resistance Meter

• Electroscope

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

 

Direction of pipe

 

• Left (B)

 

 

 

• Underside_right (C)

A

 

B

• Rear_right or left (D)

 

 

D

D

 

 

C

 

You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the

opposite direction as shown. Otherwise, the pipe may be damaged in the process.

English-35

MG_BORACAY_IB&IM_EN_DB68-05789A-00.indd 35

 

 

12/4/2015 4:48:07 PM