FixingAA the outdoor unit in place

Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).

'X' mm

'Y' mm

Rubber leg

1.Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.

2.Fix the outdoor unit in level to an appropriate support using anchor bolts.

3.If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

• Secure the rubber leg to prevent the generation of noise and vibration.

Outdoor unit installed on the wall by rack

• Ensure the wall will be able to suspend the weight of rack and outdoor unit;

• Install the rack close to the column as much as possible;

• Install proper grommet in order to reduce noise and residual vibration transferred by outdoor unit towards wall.

Model

X

Y

09/12

538

290

18/AS24

543

319

AQ24

660

340

Designed to cut off residual vibration from outdoor unit to rack.

(not supplied with product)

Soft rubber designed to cut off vibration from rack to wall. (not supplied with product)

40

UMG_AQ&AS18V@_IBIM_34038A_E--P14P18���������.indd 40

 

 

2013-3-18 11:00:20