CheckingAA before use

Operation ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

Mode

Indoor

Outdoor temperature

Indoor humidity

Remark

temperature

 

 

 

 

Cooling

 

15˚C~52˚C

 

Condensation may occur on the indoor unit

16˚C~32˚C

80% or less

with risk to have either water blow off or drops

15˚C~43˚C(AQ09)

 

 

 

on the floor.

 

 

 

 

Heating

27˚C or less

-5˚C~24˚C

-

Internal protection triggers and the air

conditioner will stop.

 

 

 

 

Dry

 

15˚C~52˚C

 

Condensation may occur on the indoor unit

18˚C~32˚C

-

with risk to have either water blow off or drops

15˚C~43˚C(AQ09)

 

 

 

on the floor.

 

 

 

 

The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition.

If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.

Maintaining your air conditioner

Internal protections via the unit control system

This internal protection operates if an internal fault occurs in the air conditioner.

Type

Description

 

 

Against cold air

The internal fan will be off to against cold air when the heat pump is heating.

 

 

De-ice cycle

The internal fan will be off to against cold air when the heat pump is heating.

 

 

Anti-protection of

The compressor will be off to protect internal battery when the air conditioner operates

internal battery

in Cool mode.

Protect compressor

The air conditioner does not start operating immediately to protect the compressor of the

outdoor unit after it has been started.

 

• If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may

have deposited at low temperatures.

The internal fan is switched off automatically and restarted only after the de-ice cycle is completed.