Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!Use a duct of the minimum indispensable length.
!Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!Avoid drastic changes in the duct
Filtration version
The aspirated air will be degreased and deodorised before being fed back into the room.
In order to use the hood in this version, you have to install a system of additional filtering based on activated charcoal.
Installation
The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 50cm from electric cookers and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area, after installation. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area, after installation, apply a double pole switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over- current category III, in accordance with installation instructions.
WARNING!
Before
The hood is provided with a special power cable ; if the cable is damaged, request a new one from Technical Service.
Mounting
Before beginning installation:
•Check that the product purchased is of a suitable size for the chosen installation area.
•Remove the charcoal (*) filter/s if supplied (see also relative paragraph). This/these is/are to be mounted only if you want lo use the hood in the filtering version.
•Check (for transport reasons) that there is no other supplied material inside the hood (e.g. packets with screws (*), guarantees (*), etc.), eventually removing them and keeping them.
Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the hood.
Do not tile, grout or silicone this appliance to the wall. Surface mounting only.
Note: The parts marked with the symbol "(*)" are optional accessories supplied only with some models or otherwise not supplied, but available for purchase.
Maintenance
Cleaning
Clean using ONLY the cloth dampened with neutral liquid detergent. DO NOT CLEAN WITH TOOLS OR INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL!
Always wear work gloves for all maintenance operations.
Grease filter
Fig.
Traps cooking grease particles.
The grease filter must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolor slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Charcoal filter (Optional)
Fig. 31
It absorbs unpleasant odors caused by cooking.
The charcoal filter can be washed once every two months (or when the filter saturation indication system – if envisaged on the model in possession – indicates this necessity) using hot water and a suitable detergent, or in a dishwasher at 65°C (if the dishwasher is used, select the full cycle function and leave dishes out).
Eliminate excess water without damaging the filter, then remove the mattress located inside the plastic frame and put it in the oven for 10 minutes at 100° C to dry completely. Replace the mattress every 3 years and when the cloth is damaged.
26
Remove the filter holder frame by turning the knobs (g) 90° that affix the chimney to the cooker hood.
Insert the pad (i) of activated carbon into the frame (h) and fit the whole back into its housing (j).
It is possible to use a traditional carbon filter, neither washable nor regenerable, to be replaced every 3 - 4 months.
The filter holder frame of the carbon filter is welded together; the eventual frame supplied with the hood is not, therefore, to be used.
Insert it into its housing and fix it turning the 2 plastic knobs.
Buying charcoal filters
The Charcoal filter can be bought at Samsung Service Website and Service Center. Please refer to the last page of manual.
Replacing lamps
The hood is equipped with a lighting system based on LED technology.
The LEDs guarantee an optimum lighting, a duration up to 10 times as long as the traditional lamps and allow to save 90% electrical energy.
For replacement, contact the technical service.
Operation
T1. ON/OFF Suction motor:
When hood is on, it switches off at any speed by pressing button T1. When the hood is off, it switches on at Speed 1 by pressing button T1.
T2. Speed decrease
Press "T2" button to decrease the speed from 4 (Boost) to 1.
T3. Speed increase
Press the button (hood is ON) to increase the the speed of the motor from speed 1 to the Boost speed (timed).
Speed 1 LED L1
Speed 2 LED L2
Speed 3 LED L3
Boost (timed) LED L4 flashing
Note: Speed 4 (Boost timed) remains activated for 5 minutes, after which the hood sets speed 2 automatically
T4. Speed timing
Speed timing is activated by pressing T4 button, when timing is up the hood switches off.
Timing is divided as follows: Speed 1 - 20 minutes (LED L1) Speed 2 - 15 minutes (LED L2) Speed 3 - 10 minutes (LED L3 ) Boost - 5 minuts (LED L4 flashing)
During timed operation press T2 button and the hood quits the timed mode and decreases the speed.
Press T3 button and the hood quits the timed mode and increases the speed. Press T4 button and the hood quits the timed mode maintaining the set speed.
T5. Lights ON/OFFF
Press the Light button and the lamps will turn on
Press the Light button again and the lamps will turn off.
Filter saturation signal button – Control and Configuration:
Grease filter signal
After 40 hours of operation LED L1 flashes.
When such signal appears, carry out grease filter maintenance.
To reset the signal, keep T1 button pressed for 3”. (hood is ON).
LED L1 stops flashing before the hood goes back to OFF.
Charcoal filter signal
After 160 hours of operation LED L2 flashes.
When such signal appears, carry out charcoal filter maintenance.
To reset the signal, keep T1 button pressed for 5”. (hood is ON).
LED L2 stops flashing before the hood goes back to OFF.