installation

Safety instructions for installation

This oven may be installed only by an approved electrician. The installer is responsible for connecting the appliance to the main supply, while observing the relevant safety regulations.

Ensure protection from live parts when installing the oven.

Power connection

If the appliance is not connected to the mains with a plug, a multi-pole isolator switch (with at least 3 mm contact spacing) must be provided in order to satisfy safety regulations. The power cable (H05 RR-F or H05 VV-F, min. 1.5~2.5 mm²) must be of sufficient length to be connected to the oven, even if the oven stands on the floor in front of its built-in cabinet. Open the rear connection cover of

the oven with a screwdriver and loosen the screws of the cable clamp before you connect the power lines to the relevant connection terminals. The oven is earthed via the ( )-terminal. The yellow and green cable (earth connection) must be connected first and be longer than the others. If the oven is connected to the mains with a plug, this plug must remain accessible after the oven is installed. Samsung will take no responsibility for accidents that originate from a missing or faulty earth connection.

 

 

 

 

 

 

BROWN

 

BLUE or

 

YELLOW

 

 

or BLACK

 

WHITE

 

and GREEN

02MAINTENANCE & INSTALLATION

WARNING: Do not allow the connecting cable to become trapped during installation, and prevent it coming into contact with hot parts of the oven.

Installation in the cabinet

With built-in furniture, plastic surfaces and adhesive for the oven should be resistant to 90 °C inside of the furniture and to 75 °C for adjacent furniture. Samsung will take no responsibility for damage of plastic surfaces or adhesive from the heat.

There should be a ventilation gap in the base of the kitchen cabinet where the oven is to be placed. For ventilation, a gap of about 50 mm should be left between the lower shelf and the supporting wall. If the oven is to be installed below a hob, the hob’s installation instructions should be followed.

 

Min.550

Min.560

 

 

 

 

Min.50

370

560

 

 

 

Max.50

 

Min.590 ~ Max.600

595

572 550

 

 

 

595

545

 

 

21

 

 

 

Min.460 x Min.50

Built-in

 

 

 

 

 

Min.550

Min.560

370

175

560

 

 

 

 

 

 

595

85

 

 

 

 

 

 

 

 

Min.600

 

 

 

 

572 550

Max. 506

 

595

Max.

 

545

Min.460 x Min.50

 

494

 

21

Built-under

 

 

 

 

 

Built-in + Built-under

Push the appliance completely into the cabinet and fix the oven firmly on both sides using 2 screws. Make sure that a gap of at least 5 mm should be left between the appliance and the adjacent cabinet.

After installation, remove the vinyl protective film, tape, paper and accessories from the door and inside of oven. Before uninstalling the oven from the furniture, disconnect the oven from the power supply and release the 2 screws on the both sides of the oven.

WARNING: The built-in furniture must have a minimum ventilation gap for Air-flow as shown in picture. Do not cover this hole with strips of wood, for this is used to provide ventilation.

The front exterior of the oven such as handle is different model by model. But the size of the oven in the picture is same.

English - 9

Neo Lite_NV70H3340BS_WT_DG68-00591B-01_EN.indd 9

2014-07-11 ￿￿ 11:11:58

Page 9
Image 9
Samsung NV70H3340BS/WT manual Installation, Safety instructions for installation