The Input source of TV works only on TV model.

The Maintenance Control function is available only for the displays where the power status is ON.

Troubleshooting

1.The display you wish to control does not appear on the Power Control Info Grid

-Check the connection of RS232C. (Check if it is properly connected to the Com1 port)

-Check the displays to see if any of the other displays connected have the same ID. If more than one displays have the same ID, those displays are not properly detected by the program due to data conflict.

-For monitors that support a Set ID between 0 to 99, you have to set the Set ID to a value between 0 and 99. Note : Check if the Set ID of the monitor is a value between 0 and 99 (set the value using the Display menu).

2.The display you wish to control does not appear on the other Control Info Grids

-Check to see if the display power is ON. (You can check this in Power Control Info Grid)

-Check if you can change the input source of the display.

3.The dialogue box appears repeatedly.

-Check to see if the display you wish to control is selected.

4.Both On Timer and Off Timer have been set but different time is showing.

-Apply current time to synchronize the display clocks.

5.The remote may not function properly when you turn off the remote Function, disconnect the RS-232C cable, or exit the program in an Irregular manner. Rerun the program and turn the remote function again to Restore normal functions.

<Note> This program may malfunction due to problems in communication circuits or interference from electronic appliances nearby.

Settings Value Display In Multiple Display Mode

When there are more than one displays connected, the settings values are displayed as follows.

1.No selection: Displays the Factory Default Value.

2.Selected one display: Fetches and displays the settings value for the selected display.

3.Selected one display (ID1) and add another display (ID3): The program, which was displaying the settings value of ID 1, fetches and displays the value of ID3.

4.If all sets are selected at the same time by clicking All and Select, the default value will be restored.