Defrost Control From 6 to 11 hrs
Defrost Thermistor(502AT) 59℉(off)
Electrical Rating AC115V 60Hz 11.6 Amps
Maximum Current Leakage 0.25 mA
Maximum Ground Path Resistance 0.1Ohm
Energy Consumption kWh/mo.
Bimetal 104℉(on)/140℉(off)
Ambient Temperature 70℉90℉
Refrigerator,℉34�46 34�46
Freezer,℉-11�7 -11�7
Run Time,% �40 �60
Refrigerant Charge (R134a) 6.17 oz
Compressor(MK183C-L2U) 1032 Btu/hr
Compressor oil Freol α-15
Capillary tube(Dia, Length)
0.033"",130""
Dryer
Molecular Sieve XH-9
Clearance must be provided for air circulation
AT TOP 1""
AT SIDES 1/8""
AT REAR 1""
RS2530, RS2630
PBA MAIN(RS2*11)∙∙∙∙∙∙∙∙∙∙DA41-00216A
PBA MAIN(RS2*21)∙∙∙∙∙∙∙∙∙∙DA41-00217B
PBA MAIN(RS2*30) ∙∙∙∙∙∙∙∙∙DA41-00218C
PBA MAIN(RS2*31) ∙∙∙∙∙∙∙∙∙DA41-00219D
PBA PANEL(RS2*11)∙∙∙∙∙∙∙∙∙DA41-00218A
PBA PANEL(RS2*21)∙∙∙∙∙∙∙∙∙DA41-00218B
PBA PANEL(RS2*30)∙∙∙∙∙∙∙∙∙DA41-00235A
PBA PANEL(RS2*31)∙∙∙∙∙∙∙∙∙DA41-00235B
TRANS DC(115V/60Hz)∙∙∙∙∙∙∙DA26-00022B
TRANS DC(220V/50,60Hz)∙∙∙∙∙DA26-00022C
TRANS DC(127V/60Hz)∙∙∙∙∙∙∙DA26-00022D
SENSOR(DEF SENSOR)∙∙∙∙∙∙DA32-00006D
SENSOR(F SENSOR)∙∙∙∙∙∙∙∙DA32-00006D
SENSOR(R SENSOR)∙∙∙∙∙∙∙∙DA32-00006B
SENSOR(ICE MAKER SENSOR)∙DA32-10108B
RELAY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙DA35-10013Q
OVERLOADED REALY ∙∙∙∙∙∙∙DA35-10013D
RUN CAPACITOR(12 ßfi)∙∙∙∙∙∙∙2501-001045
FAN MOTOR(FREEZER)∙∙∙∙∙∙DA31-00003W
FAN MOTOR(UNIT)∙∙∙∙∙∙∙∙∙∙DA31-00103A
4. SpecificationsCompressor
Dryer
Electric box
Sub-Condenser
ELECTRICAL SPECIFICATIONS Freezer Refrigerator
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
MODELS
REPLACEMENT PARTS
7