22
Function & How- to-use By Products
Press for 8 sec
Press for 8 sec
Press for 8 sec
RS2531**/RS2631**
RS2521**/RS2621**
RS2511**/RS2611**
1) Forced Operation
1-1) When pressing TEST KEY once in TEST MODE, Forced Operation shall be selected and with BEEP
sound, alarm will be operated.
1-2) If Forced Operation is selected, COMP. oper ates instantly without 5 min. delay in an y Operation MODE.
At this point, if it is in Defrost, Defrost will be stopped instantly.
1-3) With the selection of Forced Operation, COMP. and Freezer FAN operate for 24 hr. continuously and
Refrigerator shall be regulated by set temp while Forced Operation continues until the completion of
forced operation or the conversion to other MODE (forced Freezer Defrost) or cancellation.
1-4) With the selection of Forced Operation, Freezer will be selected at “ MAX(-13 °F/ -25 °C) ”and
Refrigerator will be set at “ MID (35.6 °F/ 2 °C) ”automatically. How e ver, although forced defrost or test
cancellation are selected after a minute while selecting forced operation, set temp will not change.
(Maintaining “ MAX (-13 °F/ -25 °C) ” and “ MID(35.6 °F/ 2 °C) ” ) If f orced defrost or test cancellation are
selected in a minute while selecting forced operation, set temp will go back to the previous set temp
before “ MAX (-13 °F/ -25 °C) ” and “ MID (35.6 °F/ 2 °C) ” .
1-5) On the completion of Forced Operation (24 hr.), Freezer defrost will operate regardless of the previous
state.
1-6) After the above items, it operates under the conditions of normal defrost by judging case by case.
1-7) If it is cancelled randomly during Forced Operation, (On changing into cancellation Mode), the time for
COMP. ON during forced operation shall be calculated in total and reflected in defrost cycle.
1-8) During Forced Operation, Power freezing doesn’t function and with the selection of function, LED
indication for the selected POWER function will be off after 10 sec.