25
Function & How- to-use By Products
1) Self-diagnosis with initial POWER ON
1-1) With POWER ON, it shall diagnose the status of temp SENSOR in a minute in MICOM internally for itself.
1-2) If inferior sensor is found after self-diagnosis, corresponding DISPLAY LED will be all off at the interval of
0.5 sec. and there will be no sound with LED ON.
1-3) In the state that inferior sensor is found and DISPLAY ICON is off, it only recognizes self-diagnosis KEY
(Press Ice Type KEY + FIL TER RESET KEY(LIGHT KEY) f or 8 sec.) and normal temp control will be on
hold.
1-4) On self-diagnosis ERROR, if inferior sensor is fixed or if you press ICE TYPE KEY + FILTER RESET
KEY(LIGHT KEY) for 8 sec., it will be canceled automatically.
2) Self-diagnosis during normal operation
2-1) When pressing “ ICE TYPE ” and “ FILTER RESET(LIGHT) ” KEYS simultaneously for 6 sec. in normal
operation of the fridge, temp set DISPLAY will be All ON/OFF for 2 sec. at the interval of 0.5 sec. and
when pressing “ ICE TYPE ” and “ FILTER RESET(LIGHT) ” KEYS simultaneously for 8 sec. including
TOGGLE for 2 sec., self-diagnosis will be selected.
2-2) At this point, “ SOUND ”shall be heard and it operates self-diagnosis.
2-3) When self-diagnosis operates, entire LED will be OFF and only relevant LED with malfunction will be ON
/ OFF repeatedly signifying defects. (Refer to the below self-diagnosis CHECK LIST)
2-4) When an ERROR occurs, it will be indicated for 30 sec. and restored to the normal status regardless of
maintenance.
2-5) During self-diagnosis KEY input will not be recognized.
NO Item DISPLAY LED Trouble Shooting Remark
01
02
03
04
05
06
07
Refrigerator
SENSOR
Peripheral temp
SENSOR
Freezer SENSOR
Freezer Defrost
SENSOR
Freezer Defrost
ERROR
I/M Function
ERROR
I/M SENSOR
ERROR
Refrigerator "MID"
Refrigerator "MIN"
Freezer "MAX"
Freezer "MID"
Freezer "MIN"
ICE OFF
Cubed LED
Fall out SENSOR HOUSING in Refrigerator
contanct failture, breakage of wire, short-circuit,
inferior Refrigerator SENSOR and others.
Fall out peripheral temp SENSOR HOUSING ,
contact failure, breakage of wire, short-circuit,
inferior peripheral sensor and others.
Fall out SENSOR HOUSING in Freezer, contact
failure, breakage of wire, short-circuit, inferior
Freezer SENSOR and others.
Fall out Deforst -SENSOR HOUSING in the
evaporator of Freezer, contact facilure, breakge
of wire, short-circuit, inferior sensor and
others.
Fall out Freezer Heater Housing, contact failture,
breakage of wire, short circuit, inferior Freezer
Heater, or inferior Defrost temp fuse and etc.
Ejection restoration failure more than 3 times.
Fall out I/M SENSOR HOUSING, contact
failure, brekage of wire, short-circuit, inferior
I/M-SENSOR and etc.
Indicating a defect when the temp sensing of
Refrigerator SENOSR is above (149 °F/65 °C)
and below (-58°F/-50 °C).
Indicating a defect when the temp sensing of
peripheral temp SENOSR is above (149 °F/65 °C)
and below (-58°F/-50 °C).
Indicating a defect when the temp sensing of
Freezer SENOSR is above (149 °F/65 °C) and
below (-58°F/-50 °C).
indicating a defect when the temp sensing of
Freezer Defrost SENOSR is above (149 °F/65 °C)
and below (-58°F/-50 °C).
On Freezer Defrost 90 min. automatic completion
�Details of self-diagnosis lighting by