Samsung SR-61NMC, SR-65KTC, SR-65NMC, SR-69NMC 3Forced operating and defrosting“ Beep”sound

Models: SR-61NMC SR-61KTC SR-69NMC SR-65NMC SR-65KTC

1 80
Download 80 pages 369 b
Page 14
Image 14
3)Forced operating and defrosting“( Beep”sound)

3)Forced operating and defrosting( Beepsound)

3-1) If forced function selected theBeepsounds.

3-2) Alarming sounds until the forced operating canceled by automatically(24Hr) or manualy.

3-3) Alarming sounds until the forced defrosting canceled by automatiically(24Hr) or manualy.

4)Defrosting

1-1) From the first power on, defrosting started after 4 hours of total Comp on time.

1-2) After that defrosting cycle can be varied from 6 hours to 24 hours.(Comp on time)

5)Testing

Testing is for PCB, product, function and service.

After testing, turn the power on to start self diagmosis.

1) Fored operating

1-1) As the button on PCB pushed once, Comp starts immediately.

1-2) If fored operating selected the notch of freezer and refrigerator fixed toHIGHandMID-HIGH. Then comp and F-fan is controlled to pull down and R-fan is controlled toMID-HIGHnotch.

1-3) Pull-down maintained just for 24 hours during forced operating, after that automatically defrost freezer and refrigerator and then stares nomal operating.

1-4) Turn the power off or select test cancel mode to cancel the forced operating.

1-5) Alarming (0.25 secon/0.75 sec off) continues until the forced operating finished. It continues without any relations to alarming key selection or cancel.

2) Forced defrosting

2-1) Push the test button one more time to run the forced defrosting of refrigerator.

2-2) One more push in the above status will run defrosting of freeaer and refrigerator simult a neously.

2-3) Forced operating cancelled automatically by starting forced defrosting and return to normal operating after campletion of defrosting.

3) Test cancel mode

3-1) One more push in the status of forced defrosting of F/R wiill run normal operating.

3-2) Alarming stopped in the test cancel mode.

4). Initial function of first POWER ON.

1)If power is impressed, it begins to make a self diagnosis and light all LED for 2 second if normal condition is confirmed.

2)After first self diagnosis find unstable sensor among temp. sensor. And LED is on and off 5 second periods.

3)During 2 second turn on all LED. AND F/R LED displayMID-MID

4)Early state R-EVA and F-EVA sensor is all below 15.

And R defrosting HEATER and F defrosting HEATER is perform per 0.5 second turn on.

5)After early state R-EVA sensor temp. or F-EVA sensor is over 15and F/R defrosting is end per 3 second, COMP and F-FAN, R-FAN is turn on per 0.5 second and operated per 5 minutes without temp. condition.

6)Input TEST S/W among 4) and 5) movemen 5 it is the end and perform TEST function.